Abstract

Screws of chromium-cobalt alloy and of identical dimensions but with three different surface finishes were inserted into various substances and into the bones of dogs. The torque needed to insert and remove them was measured. In vivo, and also in one in vitro setup, the highest removal torque occurred with the coarsest surface finish. Histological examination of the bone revealed the same tissue reaction to all three surface finishes. Small amounts of a black granular powder of unknown composition were found in all the sections. Weight losses were recorded for all the screws implanted. The factors influencing the torque of insertion and that of removal of a screw were discussed.

Figures in this Article
    This article is only available in the PDF format. Download the PDF to view the article, as well as its associated figures and tables.

    Topics

    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Related Audio and Videos
    PubMed Articles
    Titanium and cobalt-chrome cementless femoral stems of identical shape produce equal results.
    Clinical orthopaedics and related research: Issue date- 2004 Oct
    Third-body wear of highly cross-linked polyethylene in a hip simulator.
    The Journal of arthroplasty: Issue date- 2003 Aug
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    VA - Charleston Area Medical Center
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    Maine - Central Maine Medical Center