0
Journal Contents   |    
Results with the Constrained Total Knee Prosthesis in Treating Severely Disabled Patients and Patients with Failed Total Knee Replacements*
William L. Bargar, M.D.; Andrea CracchioloIII, M.D.; Harlan C. Amstutz, M.D.
View Disclosures and Other Information
LOS ANGELES, CALIFORNIA
Read at the Annual Meeting of The American Academy of Orthopaedic Surgeons, San Francisco, California, February 24, 1979.
Department of Surgery, Division of Orthopaedic Surgery, University of California at Los Angeles School of Medicine, Los Angeles, California 90024.

The Journal of Bone and Joint Surgery, Incorporated
The Journal of Bone & Joint Surgery.  1980; 62:504-512 
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case
text A A A

Abstract

Fifty-six constrained total knee replacements (forty Guepar and sixteen Herbert prostheses) were performed in forty-nine severely disabled arthritic patients and they were followed for two to four years. Seventeen of these knees were operated on to salvage a failed prosthesis. Good relief of pain was achieved in 64 per cent of the knees but there was less improvement in walking and function. The over-all range of motion increased because of a reduction in preoperative flexion contractures. The results in the salvage group were less successful than in those patients who underwent a primary operation. Between six months and one year postoperatively, pain had developed in 17 per cent of the fifty-six knees, 9 per cent had walking difficulties, and 7 per cent lost function. Patellofemoral pain accounted for the unfavorable pain ratings in over half of the knees.

Zonal roentgenographic analysis of each knee indicated high incidences of radiolucent lines at the cement-bone interface (75 per cent), cement-metal lucencies (68 per cent), and cement deficiencies (73 per cent). Forty-three per cent of the knees showed excessive posterior placement of the prosthesis of more than five millimeters, resulting in flexion contractures of as much as 5 degrees.

Complications requiring reoperation developed in nine knees (16 per cent). There was one case of loosening and three knees had deep infections. Chronic postoperative effusions were present in 48 per cent of the knees.

The use of either a cemented metal-on-metal hinged knee replacement or a metal-on-polyethylene hinge type of prosthesis was found to result in a relatively high incidence of failures and complications, and did not solve the problem of treating patients with a failed knee prosthesis.

Figures in this Article
    This article is only available in the PDF format. Download the PDF to view the article, as well as its associated figures and tables.

    Topics

    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Related Audio and Videos
    PubMed Articles
    Real-time myoelectric control of knee and ankle motions for transfemoral amputees.
    JAMA : the journal of the American Medical Association: Issue date- 2011 Apr 20
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    VA - Charleston Area Medical Center
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    Virginia - Charleston Area Medical Center