0
Articles   |    
Results of a second attempt at surgical repair of a failed initial rotator-cuff repair

The Journal of Bone & Joint Surgery.  1984; 66:563-567 
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case
text A A A

Abstract

Twenty-seven patients with twenty-seven involved shoulders underwent a second attempt at repair of an initial rotator-cuff repair that had failed. Factors associated with the failure of the initial repair included a massive or large tendon tear, damage to the deltoid origin at the original surgery, and possibly inadequate postoperative external support. Seven patients required a third operation because of continuing pain or weakness. The remaining twenty patients were followed for a minimum of two years (average, forty-eight months) and seventeen of them were examined at an average of forty-six months (range, twenty-six to 118 months) after surgery. Postoperatively, although seventeen patients (63 per cent) still had moderate or severe pain, sixteen (76 per cent) of the twenty-one patients who were operated on to relieve pain reported that the pain was substantially diminished. Active abduction increased an average of 8 degrees, but only seven shoulders gained more than 30 degrees of active abduction. Nineteen shoulders remained moderately or markedly weak in abduction. Over-all, four patients (17 per cent) had a good result; six (25 per cent), a fair result; and fourteen (58 per cent), a poor result. These results suggest that the surgeon should be quite hesitant to propose a second attempt at rotator cuff repair to a patient, as although pain may be diminished, active movement is unlikely to improve.

Figures in this Article
    This article is only available in the PDF format. Download the PDF to view the article, as well as its associated figures and tables.

    Topics

    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Related Audio and Videos
    PubMed Articles
    Biomechanical and Magnetic Resonance Imaging Evaluation of a Single- and Double-Row Rotator Cuff Repair in an In Vivo Sheep Model.
    Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association: Issue date- 2012 Feb 7
    Arthroscopic Partial Repair of Irreparable Large to Massive Rotator Cuff Tears.
    Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association: Issue date- 2012 Feb 6
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    VA - Charleston Area Medical Center
    12/22/2011
    Virginia - Charleston Area Medical Center