0
Articles   |    
The CAD hip arthroplasty. Five to ten-year follow-up

The Journal of Bone & Joint Surgery.  1986; 68:640-646 
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case
text A A A

Abstract

One hundred and fourteen total hip arthroplasties in 100 patients were performed using the CAD (computer-assisted design) prosthesis at The Hospital for Special Surgery between 1975 and 1977. Sixty-one of these patients (seventy-four hips) have been followed both clinically and radiographically for a minimum of five years (average, 7.1 years). While no hip required revision before five years, seven hips were revised between six and ten years postoperatively. Ten hips had an excellent result; forty-eight, good; eight, fair; and one, poor. Radiographic analysis revealed narrowing of the cortex of the bone medially at the region of the proximal part of the stem in the hips that were operated on as compared with the contralateral side that was not operated on. Nine hips (12 per cent) had one to two-millimeter radiolucent lines at the femoral bone-cement interface, and in five the lines were progressive. Fourteen hips (19 per cent) had radiolucent lines at the femoral bone-cement interface with a maximum width of 0.5 millimeter. Thirty-four (42 per cent) had more than three millimeters of resorption of the calcar or superomedial cyst formation. Survivorship analysis of the prosthesis predicted a 77 per cent survival rate at nine years. None of the prosthetic stems fractured despite the fact that the population was young, active, heavy, and predominantly male. The incidence of calcar resorption, however, was higher than in other studies. Thus, while the revision rate compared favorably with that of similar studies using other stem designs, compromise of the bone stock of the proximal end of the femur may be a significant disadvantage of this type of prosthesis.

Figures in this Article
    This article is only available in the PDF format. Download the PDF to view the article, as well as its associated figures and tables.

    Topics

    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Hip
    Related Audio and Videos
    PubMed Articles
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    VA - Charleston Area Medical Center
    12/22/2011
    Maine - Central Maine Medical Center