Direct measurement of resultant forces in the anterior cruciate ligament. An in vitro study performed with a new experimental technique

The Journal of Bone & Joint Surgery.  1990; 72:557-567 
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case
text A A A

Abstract

A new technique was used to measure the resultant forces in the anterior cruciate ligament during a series of loading experiments on seventeen fresh-frozen cadaver specimens. The base of the ligament's tibial attachment was mechanically isolated with a coring cutter, and a specially designed load-transducer was fixed to the bone-plug that contained the ligament's tibial insertion so that the resultant forces were directly measured by the load-cell. Although the magnitudes of values for forces varied considerably between specimens for a given test condition, the patterns of loading with respect to direction of loading and the angle of flexion of the knee were remarkably consistent. Passive extension of the knee generated forces in the ligament only during the last 10 degrees of extension; at 5 degrees of hyperextension, the forces ranged from fifty to 240 newtons (mean, 118 newtons). When a 200-newton pull of the quadriceps tendon was applied to extend a knee slowly against tibial resistance, however, the force in the ligament increased at all angles of flexion of the knee. Internal tibial torque always generated greater forces in the ligament than did external tibial torque; higher forces were recorded as the knee was extended. The greatest forces (133 to 370 newtons) were generated when ten newton-meters of internal tibial torque was applied to a hyperextended knee. Fifteen newton-meters of applied varus moment generated forces of ninety-four to 177 newtons at full extension; fifteen newton-meters of applied valgus moment generated a mean force of fifty-six newtons, which remained unchanged with flexion of the knee. The force during straight anterior translation of the tibia was approximately equal to the anterior force applied to the tibia. The application of 925 newtons of tibiofemoral contact force reduced the mean force in the ligament that was generated by 200 newtons of anterior pull on the tibia by 36 per cent at full extension and 46 per cent at 20 degrees of flexion.

Figures in this Article
    This article is only available in the PDF format. Download the PDF to view the article, as well as its associated figures and tables.

    Topics

    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Related Audio and Videos
    PubMed Articles
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    VA - Charleston Area Medical Center
    12/22/2011
    Maine - Central Maine Medical Center