Relative motion of hip stems under load. An in vitro study of symmetrical, asymmetrical, and custom asymmetrical designs

The Journal of Bone & Joint Surgery.  1994; 76:95-103 
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case
text A A A

Abstract

Symmetrical, asymmetrical, and custom asymmetrical stems without collars were manufactured and inserted without cement, in that order, into each of eight femora. Displacement transducers were mounted at different locations to measure relative motion between the stem and the bone. A load was applied to simulate the forces acting on a hip joint in a single-limb stance. A force of 1000 newtons was applied three times in order to seat the prosthesis, and then a cyclical force of 1000 newtons was applied to the head of the prosthesis; readings of relative motion were taken every 500 cycles, until 2500 cycles had been reached. The relative motion diminished as the number of cycles increased, with most of the reduction occurring within the first 500 cycles. The symmetrical stem had the least relative axial motion, with an average of six micrometers, but the other stems also had low values: eleven micrometers for the custom stem, and nineteen micrometers for the asymmetrical stem. In terms of axial rotation, however, the symmetrical stem had several times more motion than did the other two stems. Motion of the stem tip toward or away from the canal in the frontal plane and in the sagittal plane also was higher for the symmetrical stem. Axial migration (permanent sinkage after 2500 cycles) was very similar between all three types of stem. In a torsional loading test, the symmetrical stem showed about ten times more relative rotational motion than did the other two stems. Over-all, the custom stem and the asymmetrical stem had similar results.(ABSTRACT TRUNCATED AT 250 WORDS)

Figures in this Article
    This article is only available in the PDF format. Download the PDF to view the article, as well as its associated figures and tables.

    Topics

    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Hip
    Related Audio and Videos
    PubMed Articles
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    VA - Charleston Area Medical Center
    12/22/2011
    ME - Central Maine Medical Center