Wear of the polyethylene of Harris-Galante acetabular components inserted without cement

The Journal of Bone & Joint Surgery.  1995; 77:1311-1314 
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case
text A A A

Abstract

The amount and rate of linear wear of the polyethylene of eighty Harris-Galante acetabular components, implanted without cement during a primary or revision total hip replacement in seventy-two patients, were determined by a comparison of the thicknesses of the cup as measured on the initial and most recent follow-up radiographs. The measurements were corrected for magnification error by direct measurement of the diameter of the femoral head on each radiograph. The mean duration of follow-up was sixty-eight months (range, fifty-six to ninety-six months). Linear wear averaged 0.77 +/- 0.51 millimeter (range, zero to 1.83 millimeters) over-all, with a mean rate of 0.14 +/- 0.09 millimeter (range, zero to 0.35 millimeter) per year. An increased rate of wear per year correlated with a decreased age of the patient and with regular exercise, but there was no relationship with the weight or sex of the patient, the initial thickness of the polyethylene, or the angle of abduction of the cup.

Figures in this Article
    This article is only available in the PDF format. Download the PDF to view the article, as well as its associated figures and tables.

    Topics

    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Hip
    Related Audio and Videos
    PubMed Articles
    Groin pain after replacement of the hip: Aetiology, evaluation and treatment.
    The Journal of bone and joint surgery. British volume: Issue date- 2012 Feb
    Biomechanical Testing of Suture-Based Meniscal Repair Devices Containing Ultrahigh-Molecular-Weight Polyethylene Suture: Update 2011.
    Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association: Issue date- 2012 Feb 6
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    VA - Charleston Area Medical Center