0
Articles   |    
Digital Ischemia Associated with a Thrombosed Aneurysm of the Dorsal Interosseous Artery. A Case Report*
DERMOT A. O'FARRELL, M.CH., F.R.C.S.I.†; DAVID P. CANNON, M.D.†; JAMES A. NUNLEY, M.D.†, DURHAM, NORTH CAROLINA
View Disclosures and Other Information
Investigation performed at the Division of Orthopaedics, Department of Surgery, Duke University Medical Center, Durham
The Journal of Bone & Joint Surgery.  1997; 79:441-3 
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case
True aneurysms in the upper extremity are unusual, particularly in the absence of trauma3,9. We report the treatment of digital ischemia caused by thrombosis of an aneurysmal dorsal interosseous artery. Our report is noteworthy in that the patient also had bilateral congenital absence of the radial artery, a rare and embryologically primitive variation of human anatomy8.

*No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article. No funds were received in support of this study.

†Division of Orthopaedics, Department of Surgery, P.O. Box 2923, Duke University Medical Center, Durham, North Carolina 27710.

*No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article. No funds were received in support of this study.
†Division of Orthopaedics, Department of Surgery, P.O. Box 2923, Duke University Medical Center, Durham, North Carolina 27710.
 
Anchor for JumpAnchor for Jump
+Fig. 1 Arteriogram of the left hand, showing absent flow to the index finger and a proximal filling defect due to the thrombosed aneurysm of the dorsal interosseous artery.
 
Anchor for JumpAnchor for Jump
+Fig. 2 Arteriogram made after twenty-four hours of thrombolytic therapy, showing improved flow to the index finger and perfusion through the aneurysm.
 
Anchor for JumpAnchor for Jump
+Fig. 3 Diagram showing the anatomical site of the aneurysm, between the extensor pollicis longus tendon (EPL) and the extensor carpi radialis longus tendon (ECRL), and the skin incision used to expose the aneurysm (inset).
A fifty-five-year-old healthy woman who worked at a restaurant was referred to us because of a twenty-four-hour history of pain, numbness, and bluish discoloration of the left index finger. Clinical examination revealed an absent radial pulse and a positive Allen test7, denoting inadequate inflow through the radial artery. For the Allen test, the patient performed repeated, forceful flexion and extension of the digit while the examiner applied pressure to the volar radial and ulnar arteries at the wrist with his thumbs and pressed on the dorsal aspect of the wrist with his forefingers. When the pressure over the radial artery was released, the hand remained white and ischemic, indicating no perfusion through that artery. Sensation in the index finger was diminished, with two-point discrimination of greater than twenty millimeters. Notably, the radial pulse was not palpable at the wrist on the contralateral, asymptomatic side. Arteriography of the left upper extremity revealed a four-centimeter filling defect in what initially appeared to be an anomalous radial artery. In addition, no flow through the radial artery was seen (Fig. 1). Local intra-arterial infusion of urokinase (100,000 units per hour) was begun, and repeat angiography, twenty-four hours later, demonstrated restoration of blood flow to the affected digit. A long fusiform aneurysm was now evident at the site of the previous filling defect (Fig. 2). Clinically, the digital pain and discoloration decreased. The administration of urokinase was discontinued, and infusion of heparin (1000 units per hour) was begun.
The following day, operative exploration of the radial artery was done under pneumatic tourniquet control. A volar longitudinal incision, three centimeters long, was made just radial to the flexor carpi radialis tendon and proximal to the wrist flexion crease. The radial artery was not observed with exploration of this area. The distal part of the incision was extended by curving it dorsally around the base of the thumb, across the dorsum of the wrist to the base of the second metacarpal. The proximal part of the incision was extended longitudinally, which allowed a large flap of skin and subcutaneous tissue to be elevated, exposing the tendon sheaths of the extensor carpi radialis longus and the abductor pollicis longus. The dorsal interosseous artery was visualized in the wound, where it exited beneath the tendons of the second extensor compartment. The artery demonstrated aneurysmal dilation as well as thrombosis. Opening of the second dorsal compartment sheath and retraction of the tendon of the extensor carpi radialis longus in an ulnar direction allowed visualization of the proximal, normal, non-thrombosed portion of the dorsal interosseous artery. We then followed the thrombosed and aneurysmally dilated portion of the artery distally in the region of the anatomical snuffbox, where the most distal extent of the thrombosed vessel was located over the carpometacarpal joint of the thumb (Fig. 3). The artery was transected just proximal to the aneurysm, and the tourniquet was released to ensure normal proximal blood flow. The distal end of the aneurysm then was divided, and the entire specimen was sent for histological analysis. A graft was obtained from a superficial vein in the forearm and an end-to-end anastomosis was performed between the graft and the ends of the normal portion of the vessel with use of microsurgical technique.
Histological sections of the resected portion of the artery showed true aneurysmal dilation with organizing thrombus in the lumen. Tissue-staining for elastin showed reduplication of the internal elastic lamina, with a defect in the internal lamina of the aneurysm wall. The external elastic lamina was attenuated but preserved around the entire circumference of the artery; thus, the lesion was identified as a true rather than a false aneurysm.
Eighteen months after the operation, the graft was patent, as demonstrated by Doppler examination. An Allen test demonstrated flow through both the graft and the ulnar artery. The Allen test was done by occluding both the dorsal vein graft and the volar ulnar artery; each was sequentially released individually to demonstrate patency. Clinical testing of sensation in the left index finger at this time revealed two-point discrimination of six millimeters, compared with five millimeters in the other digits.
Spontaneous formation of an aneurysm in the upper extremity is unusual and ordinarily is the result of either repetitive or penetrating trauma. To our knowledge, the first report of a spontaneous aneurysm in the upper limb was by Griffiths in 1897; he excised an aneurysm of the ulnar artery and found histological changes of endarteritis obliterans. Kleinert et al. reported on a series of eleven aneurysms of the hand and wrist, including an aneurysm of the dorsal interosseous artery that was treated with simple excision and ligation. Those authors found that a definitive diagnosis could be made if a positive Allen test was associated with a pulsatile mass or distal vascular insufficiency, and they rarely used arteriography preoperatively. This finding conflicted with that in our patient, as the aneurysm was not pulsatile because the vessel had become thrombosed. The result of the Allen test was misleading because of the congenital absence of the radial artery and the compression of the dorsal interosseous artery during the test. When a routine Allen test is performed, the examiner applies pressure by centering his or her thumbs over the radial and ulnar aspects of the volar side of the patient's wrist7. When this is done, the examiner's index and long fingers and, occasionally, ring finger must rest on the radial and ulnar aspects of the dorsal side of the patient's wrist. To apply enough pressure with the thumbs to occlude the volar artery, the examiner must apply a large counterforce with the fingers on the dorsum of the wrist. Thus, the dorsal interosseous artery can be compressed inadvertently during the routine performance of the Allen test. The anatomical variant of absence of the radial artery was not found or described by Coleman and Anson, who studied the vascular anatomy of 650 hands and wrists.
Although some authors have doubted the benefit of fibrinolytic agents for treatment of a preformed thrombus in a small (0.82 to 1.5-millimeter) vessel2, low-dose streptokinase has been shown to be clinically effective for a thrombus in the hand if the drug is administered locally as a continuous infusion within thirty-six hours after the onset of symptoms5. Fibrinolytic agents may be helpful for an embolic occlusion of a small vessel, especially if the agent is administered shortly after the acute embolic phenomenon. This probably explains why there was excellent reperfusion of the ischemic digit in our patient after the urokinase was infused. However, the fibrinolytic agent could not remove the thrombus of the interosseous artery, which was probably not acute and may have been related to a pathological condition of the artery.
The case of our patient demonstrates some interesting features. First, a very uncommon anatomical variant of the vasculature of the upper extremity led to a misinterpretation of the preoperative arteriogram by both the surgeons and the radiologist. The study might have been misinterpreted because it was performed in one plane. If operative reconstruction is considered, arteriography should routinely be performed in two planes. Second, the findings of the Allen test were misleading because, with the test performed in the classic manner, the thumb and the forefinger of the examiner compressed the dorsal interosseous artery. Finally, for patients who are seen because of acute digital ischemia due to intravascular thrombosis, prompt commencement of local continuous infusion of streptokinase may be needed to restore blood flow; when there is a predisposing cause, arterial reconstruction may prevent repeated episodes of digital ischemia.
Coleman, S. S., and |and |Anson, B. J.: Arterial patterns in the hand based upon a study of 650 specimens. Surg., Gynec. and Obstet.,113: 409-424, 1961.113409  1961 
 
Cooney, W. P., III; Wilson, M. R.; and |and |Wood, M. B.: Intravascular fibrinolysis of small-vessel thrombosis. J. Hand Surg.,8: 131-138, 1983.8131  1983 
 
Green, D. P.: True and false traumatic aneurysms in the hand. Report of two cases and review of the literature. J. Bone and Joint Surg.,55-A: 120-128, Jan. 1973.55-A120  1973 
 
Griffiths, J.: A case of spontaneous aneurysm of the ulnar artery in the palm: excision of the aneurysm: recovery. British Med. J.,2: 646-647, 1897.2646  1897 
 
Jelalian, C.; Mehrhof, A.; Cohen, I. K.; Richardson, J.; and |and |Merritt, W. H.: Streptokinase in the treatment of acute arterial occlusion of the hand. J. Hand Surg.,10A: 534-538, 1985.10A534  1985 
 
Kleinert, H. E.; Burget, G. C.; Morgan, J. A.; Kutz, J. E.; and |and |Atasoy, E.: Aneurysms of the hand. Arch. Surg.,106: 554-557, 1973.106554  1973  [PubMed]
 
Newmeyer, W. L.: Vascular disorders. In Operative Hand Surgery, edited by D. P. Green. Vol. 2, pp. 1700-1701. New York, Churchill Livingstone, 1981. 
 
Poteat, W. L.: Report of a rare human variation: absence of the radial artery. Anat. Rec.,214: 89-95, 1986.21489  1986  [PubMed]
 
Spittel, J. A., Jr.: Aneurysms of the hand and wrist. Med. Clin. North America,42: 1007-1010, 1958.421007  1958 
 

Submit a comment

Topics

Anchor for JumpAnchor for Jump
+Fig. 1 Arteriogram of the left hand, showing absent flow to the index finger and a proximal filling defect due to the thrombosed aneurysm of the dorsal interosseous artery.
Anchor for JumpAnchor for Jump
+Fig. 2 Arteriogram made after twenty-four hours of thrombolytic therapy, showing improved flow to the index finger and perfusion through the aneurysm.
Anchor for JumpAnchor for Jump
+Fig. 3 Diagram showing the anatomical site of the aneurysm, between the extensor pollicis longus tendon (EPL) and the extensor carpi radialis longus tendon (ECRL), and the skin incision used to expose the aneurysm (inset).
Coleman, S. S., and |and |Anson, B. J.: Arterial patterns in the hand based upon a study of 650 specimens. Surg., Gynec. and Obstet.,113: 409-424, 1961.113409  1961 
 
Cooney, W. P., III; Wilson, M. R.; and |and |Wood, M. B.: Intravascular fibrinolysis of small-vessel thrombosis. J. Hand Surg.,8: 131-138, 1983.8131  1983 
 
Green, D. P.: True and false traumatic aneurysms in the hand. Report of two cases and review of the literature. J. Bone and Joint Surg.,55-A: 120-128, Jan. 1973.55-A120  1973 
 
Griffiths, J.: A case of spontaneous aneurysm of the ulnar artery in the palm: excision of the aneurysm: recovery. British Med. J.,2: 646-647, 1897.2646  1897 
 
Jelalian, C.; Mehrhof, A.; Cohen, I. K.; Richardson, J.; and |and |Merritt, W. H.: Streptokinase in the treatment of acute arterial occlusion of the hand. J. Hand Surg.,10A: 534-538, 1985.10A534  1985 
 
Kleinert, H. E.; Burget, G. C.; Morgan, J. A.; Kutz, J. E.; and |and |Atasoy, E.: Aneurysms of the hand. Arch. Surg.,106: 554-557, 1973.106554  1973  [PubMed]
 
Newmeyer, W. L.: Vascular disorders. In Operative Hand Surgery, edited by D. P. Green. Vol. 2, pp. 1700-1701. New York, Churchill Livingstone, 1981. 
 
Poteat, W. L.: Report of a rare human variation: absence of the radial artery. Anat. Rec.,214: 89-95, 1986.21489  1986  [PubMed]
 
Spittel, J. A., Jr.: Aneurysms of the hand and wrist. Med. Clin. North America,42: 1007-1010, 1958.421007  1958 
 
Accreditation Statement
These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
CME Activities Associated with This Article
Submit a Comment
Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

* = Required Field
(if multiple authors, separate names by comma)
Example: John Doe




Related Articles
Related Cases
Related Content
Topic Collections
Related Audio and Videos
PubMed Articles
Clinical Trials
Readers of This Also Read...
jbjs jobs
12/22/2011
ME - Central Maine Medical Center
12/22/2011
VA - Charleston Area Medical Center
12/22/2011
Virginia - Charleston Area Medical Center