Abstract

Background: Fixation of the femoral component of a total hip arthroplasty without cement has had variable results. While tapered stems appear to have consistently good results, the duration of follow-up in many series has been relatively short. The purpose of this study was to present a longer-term (ten to fifteen-year) follow-up after total hip arthroplasty with insertion of a tapered femoral component without cement.

Methods: Sixty-seven total hip arthroplasties were performed with insertion of a tapered, cobalt-chromium femoral component without cement in fifty-eight patients from 1983 to 1986. Thirteen patients (fifteen hips) died prior to the fifteen-year follow-up examination, and three patients (three hips) were lost to follow-up after ten years, leaving forty-two patients (forty-nine hips) who were followed clinically for a mean of fifteen years. Thirty-seven of the forty-nine hips were followed radiographically for fifteen years, and the remaining twelve were followed for a minimum of ten years.

Results: The mean preoperative Charnley score was 3.0 points for pain, 2.7 points for function, and 3.2 points for motion. At the time of the final follow-up, the mean scores were 5.6, 5.6, and 5.2 points, respectively. Although no preoperative Harris hip scores were available, the mean score at the time of the latest follow-up was 92 points (range, 78 to 100 points). There were no revisions because of isolated aseptic loosening of the femoral component (although revision because of aseptic loosening of the acetabular component led to femoral component revision in seven hips). Two femoral components showed radiographic evidence of instability. At fifteen years, the prevalence of thigh pain was 2%. No femoral component that was thought to be stable, with bone ingrowth at two years, lost fixation.

Conclusions: The design features of this cobalt-chromium femoral component (i.e., the collarless, tapered, wedge fit with circumferential porous coating) are thought to be crucial to the achievement of the good-to-excellent results seen in this study.

Figures in this Article
    Sign In to Your Personal ProfileSign In To Access Full Content
    Not a Subscriber?
    Get online access for 30 days for $30
    New to JBJS?
    Sign up for a full subscription to both the print and online editions
    Register for a FREE limited account to get full access to all CME activities, to comment on public articles, or to sign up for alerts.
    Register for a FREE limited account to get full access to all CME activities
    Have a subscription to the print edition?
    Current subscribers to The Journal of Bone & Joint Surgery in either the print or quarterly DVD formats receive free online access to JBJS.org.
    Forgot your password?
    Enter your username and email address. We'll send you a reminder to the email address on record.

     
    Forgot your username or need assistance? Please contact customer service at subs@jbjs.org. If your access is provided
    by your institution, please contact you librarian or administrator for username and password information. Institutional
    administrators, to reset your institution's master username or password, please contact subs@jbjs.org
    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Hip
    Related Audio and Videos
    PubMed Articles
    Long-term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: a 20 million cycles wear simulation.
    Journal of orthopaedic research : official publication of the Orthopaedic Research Society: Issue date- 2011 Dec
    Femoral head size does not affect ion values in metal-on-metal total hips.
    Clinical orthopaedics and related research: Issue date- 2011 Jun
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    VA - Charleston Area Medical Center
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    Maine - Central Maine Medical Center