Abstract

Background: During revision total knee arthroplasty, the alternatives for addressing the well-positioned and secure all-polyethylene patellar component with minimal or no wear include retention, revision, and resection. The purpose of the present study was to determine the intermediate-term fate of all-polyethylene patellar components that were left in situ at the time of revision tibiofemoral arthroplasty.

Methods: We retrospectively reviewed the results of 202 revision total knee arthroplasties, performed at four centers, in which a well-fixed, well-positioned all-polyethylene patellar component with minimal wear was retained. Clinical evaluation was performed to identify the presence of anterior knee symptoms or patellar failures, and the Knee Society clinical scores were recorded.

Results: Sixty-eight percent of the revision tibiofemoral components were from a different manufacturer than the retained patellar component. Twenty-one patients (twenty-one knees; 10%) reported anterior knee pain at a mean duration of follow-up of seven years (range, two to fourteen years). Eleven of the twenty-one knees with anterior knee pain had evidence of component loosening, excessive wear, or delamination either on follow-up radiographs or on direct inspection at the time of reoperation. In the other ten knees, the findings were attributable to osseous impingement on the femoral component or soft-tissue dysfunction (including soft-tissue impingement, subluxation, and scarring). Seventeen of the twenty-one patients with anterior knee pain underwent additional surgery to address the source of the pain. Failures due to loosening or wear occurred only in patients in whom the patellar component had been sterilized with gamma irradiation in air; these failures occurred at a mean 7.3 years after revision (eleven years after primary total knee arthroplasty). The likelihood of patellar component failure was significantly greater when the component had been gamma irradiated in air than when it had been sterilized with another method (p = 0.0008). The average knee score increased from 42 to 86 points, and the average function score increased from 46 to 70 points.

Conclusions: Retaining a well-positioned, stable all-polyethylene patellar component at the time of revision tibiofemoral arthroplasty can be successful, provided that the polyethylene has not oxidized. Manufacturing mismatch is acceptable with most contemporary designs provided that the patellar component articulates appropriately with the femoral implant.

Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See p. 2 for complete description of levels of evidence.

Figures in this Article
    Sign In to Your Personal ProfileSign In To Access Full Content
    Not a Subscriber?
    Get online access for 30 days for $30
    New to JBJS?
    Sign up for a full subscription to both the print and online editions
    Register for a FREE limited account to get full access to all CME activities, to comment on public articles, or to sign up for alerts.
    Register for a FREE limited account to get full access to all CME activities
    Have a subscription to the print edition?
    Current subscribers to The Journal of Bone & Joint Surgery in either the print or quarterly DVD formats receive free online access to JBJS.org.
    Forgot your password?
    Enter your username and email address. We'll send you a reminder to the email address on record.

     
    Forgot your username or need assistance? Please contact customer service at subs@jbjs.org. If your access is provided
    by your institution, please contact you librarian or administrator for username and password information. Institutional
    administrators, to reset your institution's master username or password, please contact subs@jbjs.org
    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Related Audio and Videos
    PubMed Articles
    Guidelines
    Results provided by:
    PubMed
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    VA - Charleston Area Medical Center
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    Maine - Central Maine Medical Center