0
Clinical Issues   |    
Results and Lessons Learned from a United States Hip Resurfacing Investigational Device Exemption Trial
Bernard N. Stulberg, MD1; Kathy K. Trier, PhD2; Marybeth Naughton, BS3; Jayson D. Zadzilka, MS1
1 Cleveland Clinic Orthopaedic and Rheumatologic Institute, 1730 West 25th Street, 4E, Cleveland, OH 44113. E-mail address for B.N. Stulberg: stulbeb@ccf.org
2 Corin USA, 10500 University Center Drive, Suite 190, Tampa, FL 33612
3 Stryker Orthopaedics, 325 Corporate Drive, Mahwah, NJ 07430
The Journal of Bone & Joint Surgery.  2008; 90:21-26  doi:10.2106/JBJS.H.00718
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case

Abstract

Background: Improvements in metal-on-metal bearings have made hybrid hip surface replacement a potential alternative for the young active patient with end-stage hip disease. Possible advantages include greater hip joint stability, bone preservation, and decreased osteolysis. In this study, we compared the clinical and radiographic results of a new resurfacing device with those in a historical group of standard total hip arthroplasties.

Methods: In 2001, the Cormet 2000 Hip Resurfacing Investigational Device Exemption study was initiated at twelve centers. A total of 337 patients treated with unilateral hip surface replacement with the Cormet device were enrolled in that study. These patients were compared with 266 patients in a previous study who had undergone unilateral total hip arthroplasty with ceramic bearing surfaces. Clinical and radiographic results were compared at similar time intervals. A newly recommended performance standard, the composite clinical success score, was used to assess non-inferiority of the hip resurfacing compared with the total hip arthroplasty used in the historical comparison population.

Results: At the time of follow-up, at a minimum of two years, the Harris hip scores were comparable between the resurfacing and total hip arthroplasty groups. Statistical evaluation of the composite clinical success scores confirmed the non-inferiority hypothesis. Revision was required in twenty-four patients in the resurfacing group and five patients in the total hip arthroplasty group. The most common cause of revision following resurfacing was failure of the femoral component (fracture of the femoral neck or loosening of the femoral component).

Conclusions: Careful review of this study population revealed several important criteria for successful introduction of this resurfacing device into the United States. These include careful patient selection based on clinical and radiographic parameters and attention to various surgical details of implantation. These findings can be used to focus the training process for surgeons who wish to add implantation of this device to their surgical armamentarium. Such efforts should help to ensure safe and effective introduction of this new technology.

Level of Evidence: Therapeutic Level II. See Instructions to Authors for a complete description of levels of evidence.

Figures in this Article
    Sign In to Your Personal ProfileSign In To Access Full Content
    Not a Subscriber?
    Get online access for 30 days for $30
    New to JBJS?
    Sign up for a full subscription to both the print and online editions
    Register for a FREE limited account to get full access to all CME activities, to comment on public articles, or to sign up for alerts.
    Register for a FREE limited account to get full access to all CME activities
    Have a subscription to the print edition?
    Current subscribers to The Journal of Bone & Joint Surgery in either the print or quarterly DVD formats receive free online access to JBJS.org.
    Forgot your password?
    Enter your username and email address. We'll send you a reminder to the email address on record.

     
    Forgot your username or need assistance? Please contact customer service at subs@jbjs.org. If your access is provided
    by your institution, please contact you librarian or administrator for username and password information. Institutional
    administrators, to reset your institution's master username or password, please contact subs@jbjs.org
    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Hip
    Related Audio and Videos
    PubMed Articles
    Mixing and matching causing taper wear: Corrosion associated with pseudotumour formation.
    The Journal of bone and joint surgery. British volume: Issue date- 2012 Feb
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    VA - Charleston Area Medical Center
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    Maine - Central Maine Medical Center