0
Scientific Articles   |    
Rotator Cuff Repair Augmentation in a Canine Model with Use of a Woven Poly-L-Lactide Device
Kathleen A. Derwin, PhD1; Michael J. Codsi, MD2; Ryan A. Milks, MS1; Andrew R. Baker, MS1; Jesse A. McCarron, MD1; Joseph P. Iannotti, MD, PhD1
1 Department of Biomedical Engineering, ND2-20 (K.A.D., R.A.M., and A.R.B.), and Department of Orthopaedic Surgery, A41 (J.A.M. and J.P.I.), Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44122. E-mail address for K.A. Derwin: derwink@ccf.org
2 The Everett Clinic, 3927 Rucker Avenue, Everett, WA 98201
The Journal of Bone & Joint Surgery.  2009; 91:1159-1171  doi:10.2106/JBJS.H.00775
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case

Abstract

Background: Despite advances in surgical treatment options, failure rates of rotator cuff repair have continued to range from 20% to 90%. Hence, there is a need for new repair strategies that provide effective mechanical reinforcement of rotator cuff repair as well as stimulate and enhance the intrinsic healing potential of the patient. The purpose of this study was to evaluate the extent to which augmentation of acute repair of rotator cuff tendons with a newly designed poly-L-lactide repair device would improve functional and biomechanical outcomes in a canine model.

Methods: Eight adult, male mongrel dogs (25 to 30 kg) underwent bilateral shoulder surgery. One shoulder underwent tendon release and repair only, and the other was subjected to release and repair followed by augmentation with the repair device. At twelve weeks, tendon retraction, cross-sectional area, stiffness, and ultimate load of the repair site were measured. Augmented repairs underwent histologic assessment of biocompatibility. In addition, eight pairs of canine cadaver shoulders underwent infraspinatus injury and repair with and without device augmentation with use of identical surgical procedures and served as time-zero biomechanical controls. Eight unpaired, canine cadaver shoulders were included as normal biomechanical controls.

Results: At time zero, repair augmentation significantly increased the ultimate load (23%) (p = 0.034) but not the stiffness of the canine infraspinatus tendon repair. At twelve weeks, the poly-L-lactide scaffold was observed to be histologically biocompatible, and augmented repairs demonstrated significantly less tendon retraction (p = 0.008) and significantly greater cross-sectional area (137%), stiffness (26%), and ultimate load (35%) than did repairs that had not been augmented (p < 0.001, p = 0.002, and p = 0.009, respectively).

Conclusions: While limiting but not eliminating tendon repair retraction, the augmentation device provided a tendon-bone bridge and scaffold for host tissue deposition and ingrowth, resulting in improved biomechanical function of the repair at twelve weeks.

Clinical Relevance: The augmentation device, applied in a similar manner as described in the present study, might offer a functional benefit to patients undergoing rotator cuff repair.

Figures in this Article
    Sign In to Your Personal ProfileSign In To Access Full Content
    Not a Subscriber?
    Get online access for 30 days for $30
    New to JBJS?
    Sign up for a full subscription to both the print and online editions
    Register for a FREE limited account to get full access to all CME activities, to comment on public articles, or to sign up for alerts.
    Register for a FREE limited account to get full access to all CME activities
    Have a subscription to the print edition?
    Current subscribers to The Journal of Bone & Joint Surgery in either the print or quarterly DVD formats receive free online access to JBJS.org.
    Forgot your password?
    Enter your username and email address. We'll send you a reminder to the email address on record.

     
    Forgot your username or need assistance? Please contact customer service at subs@jbjs.org. If your access is provided
    by your institution, please contact you librarian or administrator for username and password information. Institutional
    administrators, to reset your institution's master username or password, please contact subs@jbjs.org
    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Related Audio and Videos
    PubMed Articles
    Effect of varying the length of soft-tissue grafts in the tibial tunnel in a canine anterior cruciate ligament reconstruction model.
    Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association: Issue date- 2011 Jun
    Estimation of dynamic, in vivo soft-tissue deformation: experimental technique and application in a canine model of tendon injury and repair.
    Journal of orthopaedic research : official publication of the Orthopaedic Research Society: Issue date- 2011 Jun
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    VA - Charleston Area Medical Center