0
Scientific Articles   |    
Clinical Evaluation of Locking Compression Plate Fixation for Comminuted Olecranon Fractures
Geert Buijze, MD1; Peter Kloen, MD, PhD1
1 Department of Orthopaedic Surgery, Academic Medical Center, Meibergdreef 9, 1100 DD Amsterdam, The Netherlands. E-mail address for G. Buijze: g.a.buijze@amc.uva.nl. E-mail address for P. Kloen: p.kloen@amc.uva.nl
The Journal of Bone & Joint Surgery.  2009; 91:2416-2420  doi:10.2106/JBJS.H.01419
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case

Abstract

Background: In patients managed with plate fixation for the treatment of an olecranon fracture, the placement of an axial intramedullary screw may obstruct the placement of bicortical screws in the ulnar shaft. To overcome this problem, unicortical screws can be applied with use of a contoured locking compression plate. The present study was designed to assess the effectiveness of this fixation method.

Methods: Nineteen consecutive patients with an acute comminuted olecranon fracture were managed with a contoured locking compression plate and intramedullary screw fixation. Sixteen patients were available for follow-up at a minimum of twelve months after fixation. Patient-based outcomes were assessed, and patient satisfaction and pain were evaluated.

Results: All nineteen fractures healed. The mean time to fracture union was four months. The mean Disabilities of the Arm, Shoulder and Hand score was 13. According to the Mayo Elbow Performance Index and the Broberg and Morrey grading system, fifteen of the sixteen patients with at least one year of follow-up had a good or excellent outcome. Nine patients underwent hardware removal at a mean of twelve months postoperatively. The mean elbow extension deficit in these patients improved significantly from 34° to 10° following hardware removal. The mean flexion improved from 118° to 138°, but this difference was not significant.

Conclusions: In the treatment of comminuted olecranon fractures, a contoured locking compression plate combined with an intramedullary screw provides sufficient stability for early postoperative functional rehabilitation, with an excellent fracture union rate and very good clinical outcomes.

Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.

Figures in this Article
    Sign In to Your Personal ProfileSign In To Access Full Content
    Not a Subscriber?
    Get online access for 30 days for $30
    New to JBJS?
    Sign up for a full subscription to both the print and online editions
    Register for a FREE limited account to get full access to all CME activities, to comment on public articles, or to sign up for alerts.
    Register for a FREE limited account to get full access to all CME activities
    Have a subscription to the print edition?
    Current subscribers to The Journal of Bone & Joint Surgery in either the print or quarterly DVD formats receive free online access to JBJS.org.
    Forgot your password?
    Enter your username and email address. We'll send you a reminder to the email address on record.

     
    Forgot your username or need assistance? Please contact customer service at subs@jbjs.org. If your access is provided
    by your institution, please contact you librarian or administrator for username and password information. Institutional
    administrators, to reset your institution's master username or password, please contact subs@jbjs.org
    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Related Audio and Videos
    PubMed Articles
    A biomechanical comparison of multidirectional nail and locking plate fixation in unstable olecranon fractures.
    Journal of shoulder and elbow surgery / American Shoulder and Elbow Surgeons ... [et al.]: Issue date- 2011 Dec 9
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    12/22/2011
    VA - Charleston Area Medical Center
    12/22/2011
    ME - Central Maine Medical Center
    12/22/2011
    Maine - Central Maine Medical Center